Hi,

I have a question regarding IP config tool. For some reason I have not instaled 800xA on my laptop. But I have to use it to change IP address of the AC800M PLC on site.

Could you give an advice, if can I instal IPConfig tool to my laptot without installing whole 800xA system to be able to change IP address of my PLC.

Thanks.

Jiri


Add New Comment


Georgio   

asked 16 days ago
Closed



Best Answer

1

Hi,

IPconfig tool is part of Control Builder installation.

You can use IP config tool included in Compact Control Builder, it should work instead of IPconfig of 800xA.

Or use VM standalone 800xA. If your laptop does not contain 9pin serial port you will need USB-to-serial adapter.

It is possible to set IP addresses of non-redundant AC800M even without IPconfig tool. Just set new IP address of Ethernet1 and Ethernet2 of your Controller in Control Builder. Push Init button of Controller longer then 3 seconds. Change Controller identity in Control Builder then.

kamil.herman   

answered 16 days ago


 


By Georgio on 9/4/2017 | Like (0) | Report

Hi Kamil,
Thanks for your information. I just want to change IP address on my PLC, I dont have to use IPConfig tool :)
It is new information for me, that I can change IP address in the way you proposed="Just set new IP address of Ethernet1 and Ethernet2 of your Controller in Control Builder. Push Init button of Controller longer then 3 seconds. Change Controller identity in Control Builder then".

What does it mean "Change Controller identity in Control Builder then" ?
Thanks a lot.
Regards,
Jiri


By Georgio on 9/4/2017 | Like (0) | Report

But I cannot go online in Control Builder, because the PLC is part of the network. PLC has initial IP address...


By kamil.herman on 9/4/2017 | Like (0) | Report

Controller System identity is shown in parenthesis next to Controller name in CB. It can be changed by right click on controller -> Properties -> System Identity .
I cant call in mind default IP address now. It is like 172.16.35.15. Use free tool Advanced IP scanner (Radmin) to find default AC800M IP address, I have good experience with that.


By Georgio on 9/5/2017 | Like (0) | Report

Hi Kamil, OK, thanks fot the information and help :)
Regards,
Jiri


By kamil.herman on 9/5/2017 | Like (0) | Report

Ahoj Jiri, iam glad i could help. Kedykolvek, vela zdaru. Kamil


By Georgio on 9/5/2017 | Like (0) | Report

Ahoj Kamil,
I have not enough experience with ABB, I am Siemens guy :)
I have done several projects in ABB anyway - AC800M and AC450.
I am glad to learn about your code translation from AC450 to AC800M...
Jsem rad, ze jsem narazil na Vasi knihovnu prekladu kodu z AC450 na AC800M, treba to nekdy budeme potrebovat :)
Regards,
Jiri


Add New Comment


Answers

1

Hi,

IPconfig tool is part of Control Builder installation.

You can use IP config tool included in Compact Control Builder, it should work instead of IPconfig of 800xA.

Or use VM standalone 800xA. If your laptop does not contain 9pin serial port you will need USB-to-serial adapter.

It is possible to set IP addresses of non-redundant AC800M even without IPconfig tool. Just set new IP address of Ethernet1 and Ethernet2 of your Controller in Control Builder. Push Init button of Controller longer then 3 seconds. Change Controller identity in Control Builder then.

kamil.herman   

answered 16 days ago


 


By Georgio on 9/4/2017 | Like (0) | Report

Hi Kamil,
Thanks for your information. I just want to change IP address on my PLC, I dont have to use IPConfig tool :)
It is new information for me, that I can change IP address in the way you proposed="Just set new IP address of Ethernet1 and Ethernet2 of your Controller in Control Builder. Push Init button of Controller longer then 3 seconds. Change Controller identity in Control Builder then".

What does it mean "Change Controller identity in Control Builder then" ?
Thanks a lot.
Regards,
Jiri


By Georgio on 9/4/2017 | Like (0) | Report

But I cannot go online in Control Builder, because the PLC is part of the network. PLC has initial IP address...


By kamil.herman on 9/4/2017 | Like (0) | Report

Controller System identity is shown in parenthesis next to Controller name in CB. It can be changed by right click on controller -> Properties -> System Identity .
I cant call in mind default IP address now. It is like 172.16.35.15. Use free tool Advanced IP scanner (Radmin) to find default AC800M IP address, I have good experience with that.


By Georgio on 9/5/2017 | Like (0) | Report

Hi Kamil, OK, thanks fot the information and help :)
Regards,
Jiri


By kamil.herman on 9/5/2017 | Like (0) | Report

Ahoj Jiri, iam glad i could help. Kedykolvek, vela zdaru. Kamil


By Georgio on 9/5/2017 | Like (0) | Report

Ahoj Kamil,
I have not enough experience with ABB, I am Siemens guy :)
I have done several projects in ABB anyway - AC800M and AC450.
I am glad to learn about your code translation from AC450 to AC800M...
Jsem rad, ze jsem narazil na Vasi knihovnu prekladu kodu z AC450 na AC800M, treba to nekdy budeme potrebovat :)
Regards,
Jiri


Add New Comment


1

Hi Jiri,

NO, You can not install IPConfig tool seperately without Control Builder M Proffessional. It will installed with Control Builder M Proffessional only.

In case you are working on PLC Connect or Compact HMI; you have to use Compact Control Builder, which can be installed on your laptop with IPConfig tool.

Thanks,

Rachit

Rachit Khandelwal   

answered 16 days ago


 


By Georgio on 9/4/2017 | Like (0) | Report

Hi Rachit, thanks for you infomation.
Regards,
Jiri


By samir on 9/18/2017 | Like (0) | Report

HI,YOU CAN EXTRACT IN PROGRAMME FILES IN YOU COMPUTER WITCH CONTAIN 800xA SYSTEM AND JUST EXECUTE IT IN YOUR LAPTOP IT WORKS FINE BUT YOU MUST USE SERIAL CABLE


Add New Comment


1

Why not try?

I have several times successfully used the aforementioned .exe on a temporary computer, even with a USB to serial dongle.

Is it officially supported? Of course no.

Stefan Stromqvist   

answered 16 days ago


 


By Georgio on 9/5/2017 | Like (0) | Report

Hi Stefan, which .exe do you use for IP change ? Thanks, Jiri


By Stefan Stromqvist on 9/5/2017 | Like (0) | Report

Have you tried following the shortcut in the Windows Start Menu? :-)


By Georgio on 9/5/2017 | Like (0) | Report

I have no clue what do you mean :)
I just want to change the IP address of the AC800M PLC with no instaled 800xA :)
¨Best regards,
Jiri


By Stefan Stromqvist on 9/5/2017 | Like (0) | Report

A known IP can also be changed by downloading a new IP + controller reset. Set System Identity to the present address first and if needed arrange routing (eg IP alias).


Add New Comment


1

On windows 7 you can run just the IPconfig.exe , but you would probably need a mscomm32.ocx before.

Take a look at this link:

https://blogs.sap.com/2014/10/02/how-to-registeractivate-...

jesperkl   

answered 15 days ago


 


By Georgio on 9/6/2017 | Like (0) | Report

Hello, where can I get IPconfig.exe? On instalation disk of 800xA ?
Thank you.
Best regards,
Jiri


By jesperkl on 9/6/2017 | Like (0) | Report

One a 6.0.3 media disk its placed here:

D:\Engineering\Control Builder M\FirmwareFiles\bin


By Georgio on 9/6/2017 | Like (0) | Report

OK, thank you.
I will try to find and use it.
Best regards,
Jiri


Add New Comment


0

you can run the .exe as a standalone. just copy and paste it to over on a harddrive. Make sure your computer has a comm port availble in the 1-8 range before launching ipconfig. So if you're using a usb to serial converter, plug it in before launching appl or you'll get an error. i have used it several times, it works with no issues in my experience,

BK_REIS   

answered 15 days ago


 


By Georgio on 9/6/2017 | Like (0) | Report

Hello, where can I get IPconfig.exe? On instalation disk of 800xA ?
Thank you.
Best regards,
Jiri


Add New Comment



Get weekly AKS updates


Partner Exclusive Webinars

 

> – Login to the partner portal to register



Points Redemption Program - Redeem your points for ABB training, Bluetooth speakers and mugs. Terms and conditions >


Earn points when you refer a friend
AKS Referral Program is "Live" - Learn more



AKS Experts


avatar
Ask Govindaraj   

Rank: 10

Working in ABB India Operation Center. Have Project engineering and commissioning experience in ABB 800xA, Freelance, AC500.


avatar
Ask Harsha.D   

Rank: 6

Tech.Support,software and commisioning engineer with Proficient knowledge in 800xA and its products, RNRP,Networking in general.


avatar
Ask Flavio Mussolin   

Rank: 5

ABB AVP, Senior Electronic and Automation Engineer with over 30 years of experience in the field of process automation automotive, pharmaceutical, hollow glass, steel and rolling.


avatar
Ask kstoilov   

Rank: 21

Control System Engineer: 800xA, Compact 800, AC500, AC31-50, Advant Master, Simatic, AC&DC Drives 11 years worked for ABB - Control Systems


avatar
Ask nikismith   

Rank: 260

I have been a part of the Recording & Control Factory team for 17 years in total, having spent a number of years as a repairs technician withi the manufacturing department, but being in my current role for 9 years now.


avatar
Ask MMM   

Rank: 4

ABB PA CT Technical Support


avatar
Ask Rob Lyon   

Rank: 3

info@lymac.co.nz I'm an independent DCS software and commissioning engineer with extensive experience in 800xA and other ABB products. I've worked in almost every corner of the world and still haven't seen it all.


avatar
Ask Stefan Stromqvist   

Rank: 1

I joined ABB in the year of 1994 and has since 1999 been working as a Service & Support Engineer at BU Control Technologies in Västerås, Sweden. My areas of expertise are: 800xA Base, 800xA for Advant Master, Information Management, operating systems, RNRP and Ethernet comms/networking in general.


avatar
Ask Sumit Gargav   

Rank: 2

I have worked with Freelance in majority, with 800xA FD and Melody system partly. Also had opportunity to work with Protocols - HART,Profibus,FF & Modbus.


avatar
Ask Dieter Henkel   

Rank: 24